Discontinued Products for Sale

GE

Part Number 405813 – GE M-Pact Plus ACB, Non-auto 1600A type S (50kA) moving portion, 3-pole..............2 off available..


SIEMENS

1 off 3WN6283-0FB58-1KA1-Z K03+R20

WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=1000A TO 690V, AC50/60HZ ICU=65KA AT 500V WITH READY-TO-CLOSE SIGNALLING SWITCH WITH MECHANICAL RECLOSING LOCK-OUT WITH TRIPPED SIGNALLING SWITCH WITH TRIPPED INDICATORS WITH GUIDE FRAME Overcurrent release AZN Version B Setting range 400...1000 A Motorized/manual operating mechanism with memory with electrical and mechanical activation Motor and electr. calling for 220...240 V AC, 220...250 V DC With 1st auxiliary release Shunt release "F", F1 220...240 V AC, 220...250 V DC without 2nd auxiliary release Switch position-depending auxiliary current switches 2 NC+2 NO Rated short-time withstand current ICW 50 kA/1s, 4-pole 2-piece shutter

1 off 3WN6183-0EB58-1KA1-Z K03+R20+R53

WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE I IN=800A TO 690V, AC50/60HZ ICU=65KA AT 500V WITH READY-TO-CLOSE SIGNALLING SWITCH WITH MECHANICAL RECLOSING LOCK-OUT WITH TRIPPED SIGNALLING SWITCH WITH TRIPPED INDICATORS WITH GUIDE FRAME Overcurrent release AZN Version B Setting range 320...800 A Motorized/manual operating mechanism with memory with electrical and mechanical activation Motor and electr. calling for 220...240 V AC, 220...250 V DC With 1st auxiliary release Shunt release "F", F1 220...240 V AC, 220...250 V DC without 2nd auxiliary release Switch position-depending auxiliary current switches 2 NC+2 NO Rated short-time withstand current ICW 50 kA/1s, 4-pole 2-piece shutter Mutual mechanical interlock

1 off 3WN6583-0JB58-1KA1-Z+R20+R53

 WITHDRAWABLE CIRCUIT BREAKER 4-POLE, SIZE II IN=2000A TO 690V, AC50/60HZ ICU=80KA AT 500V WITH READY-TO-CLOSE SIGNALLING SWITCH WITH MECHANICAL RECLOSING LOCK-OUT WITH TRIPPED SIGNALLING SWITCH WITH TRIPPED INDICATORS WITH GUIDE FRAME Overcurrent release AZN Version B Setting range 800 ... 2000 A Motorized/manual operating mechanism with memory with electrical and mechanical activation Motor and electr. calling for 220...240 V AC, 220...250 V DC With 1st auxiliary release Shunt release "F", F1 220...240 V AC, 220...250 V DC without 2nd auxiliary release Switch position-depending auxiliary current switches 2 NC+2 NO 2-piece shutter Mutual mechanical interlock

  

1 off 3WL9212-6AD00-1BA1

Accessory for switch 3WL Guide frame size 2 4000 A 3-pole, rear vertical connection Without auxiliary plug connectors without auxiliary current plug connectors With 3 change-over contacts, Operation 1 CO, Test 1 CO, Isolated position 1 CO With 2-piece shutter, can be locked

  

1 off 3WL1240-3FB47-4GA2-Z T40

Draw-out circuit breaker with slide-in module frame 4-pole, Size 2, IEC In=4000 A up to 690 V, 50/60 Hz AC Icu=80 kA at 500 V Rear vertical connection Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with memory Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC T40= Door sealing frame

  

1 off 3WL9212-3BD00-0AA1

Accessory for switch 3WL guide frame size 2 2000 A 4-pole, rear vertical connection Without auxiliary plug connectors without auxiliary current plug connectors without position signaling switch without shutter